Osteoblast Response to Porous Titanium Surfaces Coated with Zinc-Substituted Hydroxyapatite

Fan Yang,Wen-jing-Dong,Fu-ming He,Xiao-xiang-Wang,Shi-fang Zhao,Guo-li Yang
DOI: https://doi.org/10.1016/j.tripleo.2011.02.049
2012-01-01
Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Abstract:Background. The aims of this study were to deposit a zinc-hydroxyapatite (Zn-HA) coating on titanium surfaces by using the electrochemical process and investigate the cell response to the Zn-HA-coated titanium surface.Study Design. Surface characteristics were evaluated by scanning electron microscopy (SEM) and inductively coupled plasma atomic emission spectroscopy (ICP-AES). Murine preosteoblast cell (MC3T3-E1) proliferation, alkaline phosphatase (ALP) activity, and osteocalcin release on Zn-HA-coated surfaces were compared with HA-coated surfaces.Results. Field-emission SEM observation showed rod-like HA crystals with a hexagonal cross-section on the HA-coated surface, although the hexagon of the cross-section of Zn-HA crystals became irregular. ICP-AES analysis showed that Zn was present in the Zn-HA coatings at a Zn/(Ca+Zn) molar ratio of 1.04%. Significant increases in cell proliferation, ALP activity on day 7, and osteocalcin produnction on day 14 (P < .05) were observed for Zn2+-containing HA-coated surfaces.Conclusions. The present study showed that a Zn-HA coating deposited by using the electrochemical process enhances proliferation and differentiation of osteoblasts, which has the potential benefit to enhance implant osseointegration. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;113:313-318)