Monte Carlo simulation of neutron sensitivity of microfission chamber in neutron flux measurement

Jiang, Xin-Biao
DOI: https://doi.org/10.1007/s41365-022-01062-6
2022-07-09
Nuclear Science and Techniques/Hewuli
Abstract:Microfission chambers loaded with highly enriched fissile materials are widely used for measuring power in reactors. The neutron sensitivity of the microfission chamber is a key parameter that determines the accuracy of the power measurement. To evaluate the performance of the FC4A microfission chamber, in this work, we introduced an accurate and validated model of the microfission chamber, a performed Monte Carlo simulation of the neutron sensitivity of the microfission chamber with GEANT4 code, and conducted an irradiation experiment on the neutron irradiation effect platform #3 of the Xi'an Pulsed Reactor. We compared the simulated sensitivity with the experimental results, which showed that the sensitivity obtained from the simulation was in good agreement with the experimental results. In addition, we studied the impact of the design parameters of the fission chamber on the calculated neutron sensitivity of the microfission chamber.
What problem does this paper attempt to address?