MONTE CARLO SIMULATION STUDY ON THE <SUP>241</SUP>Am-Be RADIONUCLIDE SOURCE REFERENCE NEUTRON RADIATION

Yixin Liu,Song Zhang,Yikun Qian,Yuchen Huang,Benjiang Mao,Peng Feng,Zhiqiang Chen
DOI: https://doi.org/10.2298/NTRP2004283L
2020-01-01
Abstract:In order to study the feasibility of using lightweight Am-241-Be radionuclide reference neutron radiation field for the calibration of neutron measurement instruments, this paper reported the Monte Carlo simulation work on free field reference neutron radiation, standard reference neutron radiation regulated by ISO-8529 series standards and minitype reference neutron radiation we designed. The distributions of dose equivalent rates and neutron energy spectrum in different conditions, such as different room types, different room sizes and different shield materials were the main simulation contents for analyzing the characteristics of the three types of reference neutron radiation. According to the simulation results, theoretical sup ports were provided for the discussion on the minitype reference neutron radiation for calibration purpose.
What problem does this paper attempt to address?