Calculations of Dose and Ambient Dose Equivalent in Radiation Field for Am-Be Neutron Source

刘镇洲,陈金象
2009-01-01
Abstract:For neutron energy ranging from thermal to 20 MeV,kerma coefficients of elements H,C,N,O,Ar,dry air,and the ICRU 4-element tissue,were deduced from lately updated microscopic cross sections(ENDF/B-Ⅶ).On the base of these kerma coefficients and Monte-Carlo simulation using the MCNP code,ambient dose equivalent for unit neutron fluence of Am-Be source was calculated as 373.0 pSv·am2.Besides,based on the neutron spectrum of a Chinese-made Am-Be source calculated by our group,the ambient dose equivalent was calculated as 374.0 pSv·cm2.Neutron and γ-ray absorbed dose rate in the air at 1 m distance from the source were calculated with the results of 1.457×10-2 and 1.580×10-1 μGy/(GBq·h),respectively.
What problem does this paper attempt to address?