Dose Coefficient Calculation of External Exposure of Radionuclides Based on Chinese Reference Voxel Phantom

LU Wei,WU Zhen,QIU Rui,LI Chunyan,YANG Bo,LI Junli
DOI: https://doi.org/10.3969/j.issn.1001-246x.2016.05.014
2016-01-01
Abstract:Dose coefficients for external photon radiation are widely used for assessment of radiation dose to public and workers due to ground surface contamination and air immersion of radionuclides released in nuclear accidents. Dose coefficients based on Chinese reference voxel phantom were presented. Photons that incident into the cylinder, which is slightly larger than phantom, is simulated using Geant4, including distributions of angle, height and energy of photons; Secondly, photons are sampled on surface of cylinder around Chinese Reference Male/Female Voxel Phantom with MCNPX 2?4?k from the above source, dose coefficients of 20 initial gamma ray energies, from 15keV to 10 MeV, are calculated. Thirdly, dose coefficients of 68 important nuclides are evaluated by combining of decay data from ICRP 107 and photon coefficients using cubic?spline fitting. GB/T 17982?2000 shows an overestimation for ground contamination while an underestimation of high Z nuclides for air immersion compared to our results.
What problem does this paper attempt to address?