The Internal Radiation Dose Calculations Based on Chinese Mathematical Phantom

WANG Hai-yan,LI Jun-li,CHENG Jian-ping,FAN Jia-jin,ZHENG Jun-zheng
DOI: https://doi.org/10.3969/j.issn.0258-0934.2006.06.061
2006-01-01
Abstract:The internal radiation dose calculations built on Chinese facts become more and more important according to the development of nuclear medicine.The MIRD method developed and consummated by the society of Nuclear Medicine(America) is based on the European and American mathematical phantom and can't fit Chinese well.The transport of γ-ray in the Chinese mathematical phantom was simulated with Monte Carlo method in programs as MCNP4C.The specific absorbed fractions(Φ) of Chinese were calculated and the Chinese Φ database was created.The results were compared with the recommended values by ORNL.The method was proved correct by the coherence when the target organ was the same with the source organ.Else,the difference was due to the different phantom and the choice of different physical model.
What problem does this paper attempt to address?