Failure Analysis of Utility Boiler Superheater Tubes of A213 T12

Ali Karimi
DOI: https://doi.org/10.1007/s11668-022-01550-2
2022-11-29
Journal of Failure Analysis and Prevention
Abstract:Different parts of two adjacent superheater tubes of boiler were overheated. The outside surface of failed tubes was exfoliated and tarnished. Visual examination of superheater was done. Deposits caused blockage of steam through tubes far away from failure locations. Tube temperature raised and caused oxidation and long-term overheat. The tubes are sectioned longitudinally, and internal surface was inspected. The tubes were plugged by a hard and sticky scale and deposit. Precipitation mechanisms were investigated by considering the boiler feed water treatment, boiler operation history, chemical analysis of boiler water. x-ray diffraction (XRD) analysis was conducted to specify the deposit. Analysis shows that deposit mostly consists of sodium compounds, silica, and iron oxide. These compounds were entrained by water droplet and carried over by steam because of foaming due to solid content and alkalinity of boiler water. The cause of failure was illustrated by presenting a fault tree analysis (FTA), determining main root cause, and contributing factors. Possible solutions to reduce boiler tube failure rate was discussed.
What problem does this paper attempt to address?