Abstract:With no doubt, shell-and-tube heat exchangers are playing a crucial role in refineries. The heat exchanger shell environment in this study was rich in hydrocarbon, hydrogen, H2S, and water, but the fluid in the tube was chilled water. Many leak points were found in the tube-to-tubesheet welded joints. The failure at the tube-to-tubesheet welded joints was investigated using different approaches, including examining the chemical and mechanical properties of failed sample tube and standard tube, besides reviewing the equipment history. This work revealed that the fatigue started at the initial crack at the tube-to-tubesheet welded joint; it was the main failure mechanism besides other factors that helped to weaken the welded joints such as vibration, using seal weld instead of strength weld, expanding the tube before welding, and weld quality. This study found evidence of cooling water corrosion and fouling inside the tubes due to cooling drop and low velocity.