Real-Time Series Resistance Monitoring in PV Systems Without the Need for I–V Curves

Michael G. Deceglie,Timothy J. Silverman,Bill Marion,Sarah R. Kurtz,Timothy J Silverman
DOI: https://doi.org/10.1109/jphotov.2015.2478070
2015-11-01
IEEE Journal of Photovoltaics
Abstract:We apply the physical principles of a familiar method, suns-Voc, to a new application: the real-time detection of series resistance changes in modules and systems operating outside. The real-time series resistance (RTSR) method that we describe avoids the need for collecting I-V curves or constructing full series resistance-free I-V curves. RTSR is most readily deployable at the module level on microinverters or module-integrated electronics, but it can also be extended to full strings. Automated detection of series resistance increases can provide early warnings of some of the most common reliability issues, which also pose fire risks, including broken ribbons, broken solder bonds, and contact problems in the junction or combiner box. We describe the method in detail and describe a sample application to data collected from modules operating in the field.
energy & fuels,materials science, multidisciplinary,physics, applied
What problem does this paper attempt to address?