Design and Development of a New Smart Portable I-V Tracer

Navid Tavakoli,Pascal Koelblin,Michael Saliba
DOI: https://doi.org/10.1109/jphotov.2024.3438451
2024-10-29
IEEE Journal of Photovoltaics
Abstract:Photovoltaic (PV) module performance is primarily characterized by their current-voltage (I-V) measurements. However, the data obtained mostly contains errors. Commercial I-V curve tracking units are generally expensive, hard to transport, slow to respond, and limited at low irradiations. This article proposes a novel I-V tracer (SEPIV) based on an optimized single-ended primary inductance converter. The SEPIV comprises a linear variable dc load connected to the solar panel's output. In this study, the experimental performance of the SEPIV was compared with the outcomes of commercial and lab devices, which are PVPM 1000 C 40 (PVPM) and WAVELABS SINUS-3000 PRO, respectively. SEPIV's accuracy matched lab units and surpassed PVPM's. As a highlight of this study, the introduced setup can capture the I-V curves of PV modules up to 650 W, a maximum VOC of 60 V, and a maximum ISC of 20 A. In contrast to commercial units, the SEPIV measurement does not depend on irradiation level. Moreover, it has the Internet of Things capability through a Wi-Fi connection for remote measurement.
energy & fuels,materials science, multidisciplinary,physics, applied
What problem does this paper attempt to address?