Abstract:In the following study cost estimates have been undertaken for an encapsulated phase change material (EPCM) packed bed, a packed bed thermocline and a traditional two-tank molten salt system. The effect of various heat transfer fluids (air and molten salt), system configuration (cascade vs one PCM, and direct vs indirect) and temperature difference (ΔT = 100-500 °C) on the cost estimate of the system was also investigated. Lastly, the storage system boundary was expanded to include heat exchangers, pumps and fans, and heat tracing so that a thorough cost comparison could be undertaken. The results presented in this paper provide a methodology to quickly compare various systems and configurations while providing design limits for the studied technologies.