Automatic rough alignment for key components in laser driven experiments using fiducial markers

D C Popescu,M O Cernaianu,I Dumitrache
DOI: https://doi.org/10.1088/1742-6596/1079/1/012013
2018-08-01
Journal of Physics: Conference Series
Abstract:Abstract In the laser - solid target experiments at ELI-NP, maximizing the availability of the laser system and hence the number of shots during a campaign is envisaged. One of the factors that affects this is the time for preparing the experiment and the time for changing the targets between shots. In this paper we present a method for automatic rough alignment of various experimental setup instruments like the target frames, microscopes and diagnostics. Giving the impossibility to define a global reference system that captures precisely enough the relative position of all equipment in a continuously changing experimental setup, the method developed is using relative optical measurements using fiducial markers. The method is conceived to be used along with other micron-level alignment methods as a pre-alignment phase. Along this work, a setup and the algorithms were developed in order to test the accuracy of the method. First tests revealed a rough alignment accuracy between 100-200μm which was achieved using only a low resolution imaging camera. The accuracy can be further improved using higher resolution imaging systems or by developing new key points in the algorithm that are discussed at the end of the paper.