Numerical Model of Direct Internal Reforming SOFC: A Comparison between Anode-Support and Metal-Support

Yuqing Wang,Jiawei Ren,Yixiang Shi,Xiaofeng Li
DOI: https://doi.org/10.1149/09101.2013ecst
2019-07-10
ECS Transactions
Abstract:Direct internal reforming (DIR) operation provides many benefits for solid oxide fuel cells (SOFCs) by eliminating the need for an extra reformer. Anode-supported SOFCs (AS-SOFCs) are commonly used for DIR operations. However, the strong endothermic reforming reactions at the cell entrance may result in large thermal stresses and lead to premature failure. In this study, a two-dimensional model was developed to analyze the differences between the AS-SOFC and the new generation metal-supported SOFC (MS-SOFC) in DIR operations. The model considered the coupling effects of the chemical/electrochemical reactions, the mass/charge/heat transport processes and the thermal mechanical stress. The distributions of temperature, species composition, current density and thermal stress were determined and compared for both structures. The failure probability of the cell was estimated by stress distributions. The results showed that the MS-SOFC led to a gentler temperature distribution and a smaller failure probability with slight performance increase compared to the AS-SOFC.
What problem does this paper attempt to address?