Direct thermal neutron detection by the 2D semiconductor 6LiInP2Se6

Daniel G. Chica,Yihui He,Kyle M. McCall,Duck Young Chung,Rahmi O. Pak,Giancarlo Trimarchi,Zhifu Liu,Patrick M. De Lurgio,Bruce W. Wessels,Mercouri G. Kanatzidis
DOI: https://doi.org/10.1038/s41586-019-1886-8
IF: 64.8
2020-01-15
Nature
Abstract:Highly efficient neutron detectors are critical in many sectors, including national security<sup><a href="/articles/s41586-019-1886-8#ref-CR1">1</a>,<a href="/articles/s41586-019-1886-8#ref-CR2">2</a></sup>, medicine<sup><a href="/articles/s41586-019-1886-8#ref-CR3">3</a></sup>, crystallography<sup><a href="/articles/s41586-019-1886-8#ref-CR4">4</a></sup> and astronomy<sup><a href="/articles/s41586-019-1886-8#ref-CR5">5</a></sup>. The main neutron detection technologies currently used involve <sup>3</sup>He-gas-filled proportional counters<sup><a href="/articles/s41586-019-1886-8#ref-CR6">6</a></sup> and light scintillators<sup><a href="/articles/s41586-019-1886-8#ref-CR7">7</a></sup> for thermalized neutrons. Semiconductors could provide the next generation of neutron detectors because their advantages could make them competitive with or superior to existing detectors. In particular, solids with a high concentration of high-neutron-capture nuclides (such as <sup>6</sup>Li, <sup>10</sup>B) could be used to develop smaller detectors with high intrinsic efficiencies. However, no promising materials have been reported so far for the construction of direct-conversion semiconductor detectors. Here we report on the semiconductor LiInP<sub>2</sub>Se<sub>6</sub> and demonstrate its potential as a candidate material for the direct detection of thermal neutrons at room temperature. This compound has a good thermal-neutron-capture cross-section, a suitable bandgap (2.06 electronvolts) and a favourable electronic band structure for efficient electron charge transport. We used α particles from an <sup>241</sup>Am source as a proxy for the neutron-capture reaction and determined that the compact two-dimensional (2D) LiInP<sub>2</sub>Se<sub>6</sub> detectors resolved the full-energy peak with an energy resolution of 13.9 per cent. Direct neutron detection from a moderated Pu–Be source was achieved using <sup>6</sup>Li-enriched (95 per cent) LiInP<sub>2</sub>Se<sub>6</sub> detectors with full-peak resolution. We anticipate that these results will spark interest in this field and enable the replacement of <sup>3</sup>He counters by semiconductor-based neutron detectors.
multidisciplinary sciences
What problem does this paper attempt to address?