GAMBE: Thermal neutron detection system based on a sandwich configuration of silicon semiconductor detector coupled with neutron reactive material

A. Omar,S. Burdin,G. Casse,H. van Zalinge,S. Powel,J. Rees,A. Smith,I. Tsurin
DOI: https://doi.org/10.1016/j.radmeas.2019.01.019
IF: 1.743
2019-03-01
Radiation Measurements
Abstract:Silicon semiconductor detectors are used efficiently for neutron detection when coated with a suitable material. They detect secondary reaction products resulting from the interaction of thermal neutrons with a neutron sensitive material such as 6LiF. In the present work, the efficiency of the thermal neutron detector system, GAMBE, is discussed. This detector system based on two silicon sensors of 1 cm2 active area and a layer of 6LiF ( 1.5 ± 0.6 ) mg/cm2 thick in a sandwich configuration. This arrangement achieves total and coincidence detection efficiency of ( 4.1 ± 0.5 )% and ( 0.9 ± 0.3 )% respectively. The coincidence method defines a true neutron hit by the simultaneous signal recorded by the two sensors facing the conversion film. This coincidence methodology is applied to enhance the rejection factor of fake hits due to high gamma background conditions up to 108 as discussed in previous work. Geant simulation indicates that total and coincidence detection efficiency up to 55% and 18% are possible using an advanced design of stacked detectors.
nuclear science & technology
What problem does this paper attempt to address?