CFD simulation and analysis of reactive flow for dissolved manganese removal from drinking water by aeration process using an airlift reactor

Sanaa Kouzbour,Youssef Stiriba,Bouchaib Gourich,Christophe Vial
DOI: https://doi.org/10.1016/j.jwpe.2020.101352
IF: 7
2020-08-01
Journal of Water Process Engineering
Abstract:Removal of soluble manganese Mn(II) from natural water using dissolved oxygen as an oxidant is an important process in the production of drinking water. This process can be performed in multiphase devices, and airlift reactors have been regarded as an efficient system for carrying out aeration. To simulate this process, it is necessary to understand the oxidation kinetics of soluble Mn(II) coupled to multiphase hydrodynamics and inter-phase mass transfer. The objective of this paper is, therefore, to develop a three-dimensional Euler-Euler two-phase model, aiming to simulate a reactive flow for Mn(II) removal from drinking water by aeration process using an airlift reactor. Based on the previous experimental data, the mathematical models were firstly validated by comparing the liquid residence time distribution and mass transfer, and then the dependence of manganese oxidation on the initial Mn(II) concentration and pH values were analysed. Afterwards, the dependence of manganese oxidation on the initial Mn(II) concentration and pH values were numerically analysed, as well as the effect of the autocatalytic reaction due to the addition of MnO2, and compared to the results from a one-dimensional axial dispersion model. Using CFD, it was found that the local and global models agreed successfully with experimental data and correctly described the auto-catalytic effect of MnO2 on the oxidation by aeration process. While the level of spatial heterogeneity increased with pH, the simulations highlighted surprisingly that it decreased with a rise in the initial concentration of MnII, whereas it remained constant when the amount of MnO2 was increased.
engineering, chemical, environmental,water resources
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the removal of dissolved manganese (Mn(II)) in drinking water through the aeration process. Specifically, the paper focuses on how to simulate and analyze the reaction fluid dynamics during aeration treatment using an air - lift reactor in order to improve the manganese removal efficiency. The paper mentions that the removal of dissolved manganese is crucial for producing water that meets drinking standards, but the natural aeration process is difficult to achieve the desired effect due to the slow oxidation kinetics. Therefore, the research aims to develop a three - dimensional Euler - Euler two - phase model for simulating the process of removing dissolved manganese through aeration in an air - lift reactor. This not only helps to understand the coupling relationship between oxidation kinetics, multiphase fluid mechanics and inter - phase mass transfer, but also provides theoretical guidance and technical support for practical applications. The paper verifies the validity of the mathematical model through experimental data, especially the liquid - phase residence time distribution and mass - transfer performance, and analyzes the influence of the initial Mn(II) concentration and pH value on manganese oxidation. In addition, the autocatalytic reaction effect caused by the addition of MnO2 is also explored. The research results show that the local and global models are in good agreement with the experimental data and can accurately describe the autocatalytic effect of MnO2 on oxidation during the aeration process. As the pH value increases, the level of spatial heterogeneity increases, but as the initial Mn(II) concentration increases, the spatial heterogeneity decreases, while when the amount of MnO2 increases, the spatial heterogeneity remains unchanged. In conclusion, this research aims to optimize the process of removing dissolved manganese in drinking water through advanced computational fluid dynamics (CFD) technology, especially in the application scenario of air - lift reactors, and provide more efficient and economical solutions.