Simulation of indoor pollutant diffusion concentration field in passive house based on CFD software

Huangyuan Wu
DOI: https://doi.org/10.1088/1755-1315/558/4/042045
2020-08-01
IOP Conference Series: Earth and Environmental Science
Abstract:Abstract Due to the good air tightness of the passive house, once there are poor quality furniture materials in the room, it is easy to cause indoor formaldehyde pollution which do harm to people’s health as well as the quality of their life. This article introduces the CFD software to simulate the change of indoor formaldehyde concentration in the passive house when opening the fresh air system to ensure indoor air quality and to employ a new way to the better quality of life of residents. The function of CFD software and two fluid dynamics control equations are introduced in the essay, and the finite difference method of control equation discretization is studied as well. Based on CFD software, the case is analyzed, under which the indoor formaldehyde concentration changes, according to different fresh air system inlet locations. The simulation results show that when the two air outlets of the living room are on the side of the sofa and TV cabinet, and the air outlet of the bedroom is in the corner, the formaldehyde purification rate is better, which a more reasonable air supply method is.
What problem does this paper attempt to address?