Three-dimension Large Eddy Simulation of Indoor Air Pollution

WU Meng,HU Gui-lin,FAN Jian-ren,CEN Ke-fa
DOI: https://doi.org/10.3785/j.issn.1008-973x.2006.06.014
2006-01-01
Abstract:To improve the effect of natural ventilation in diluting indoor air pollutant,the rules of indoor air pollutant under ventilation with window were investigated.The process of indoor air pollutant's dilution under natural ventilation in an apartment was simulated with software Fluent 6.1 and large-eddy simulation(LES).Two cases were set according to different room types and hatch collocation,and data on flow field and pollutant mass fraction field were obtained.The numerical simulating results show that flow field vortexes adversely influence the ventilation.Multi-hatch rooms have higher flow speed and smaller vortex than single-hatch rooms,the speed of indoor air pollutant's dilution in multi-hatch rooms is 4~10 times that of single-hatch rooms.Changing single-hatch rooms into multi-hatch rooms,reducing and breaking vortexes in multi-hatch room can effectively accelerate the dilution of indoor air pollutant.
What problem does this paper attempt to address?