Field demonstration of a 10 MW CO 2 capture pilot plant in extended operation using KoSol absorbents for treating off-gas in a coal fired power plant
No-Sang Kwak,Jinkyu Jung,Junghyun Lee,Sung-Chul Han,Jae-Goo Shim,Kyung-Min Kim,Doh C. Lee
DOI: https://doi.org/10.1016/j.ijggc.2024.104134
IF: 4.4
2024-04-28
International Journal of Greenhouse Gas Control
Abstract:Efficient CO 2 absorbents are crucial for reducing energy use in CO 2 capture absorption process. This study evaluates the performance of amine-based CO 2 absorbents, KoSol-5 and KoSol-6, developed by the Korea Electric Power Corporation. In a 10 MW pilot plant, KoSol-6 was found to capture more than 90% of the daily CO 2 emissions, amounting to over 180 tons per day, from the exhaust gasses of a coal-fired power plant. Its regeneration energy ( Q regen ) was 2.42 GJ/ton CO 2 in the standard absorption process, which is 39.2% less than the monoethanolamine (MEA) system. Implementing advanced techniques like intercooling, lean vapor compression, and thermal vapor recompression further optimized this process. Among these, the thermal vapor recompression mode turned out to be the most efficient and stable. In addition, KoSol-6 showcased excellent thermal and chemical stability, with a consistent Q regen of 2.34 GJ/ton CO 2 over a 10,000-hour test. The study provides insights into the potential of KoSol-5 and KoSol-6 for large-scale applications and further developments in CO 2 capture technology.
energy & fuels,engineering, chemical, environmental,green & sustainable science & technology