Spatial Trueness Evaluation of 3D-Printed Dental Model Made of Photopolymer Resin: Use of Special Structurized Dental Model
Aonan Wen,Ning Xiao,Yujia Zhu,Zixiang Gao,Qingzhao Qin,Shenyao Shan,Wenbo Li,Yuchun Sun,Yong Wang,Yijiao Zhao
DOI: https://doi.org/10.3390/polym16081083
IF: 5
2024-04-13
Polymers
Abstract:(1) Background: Various 3D printers are available for dental practice; however, a comprehensive accuracy evaluation method to effectively guide practitioners is lacking. This in vitro study aimed to propose an optimized method to evaluate the spatial trueness of a 3D-printed dental model made of photopolymer resin based on a special structurized dental model, and provide the preliminary evaluation results of six 3D printers. (2) Methods: A structurized dental model comprising several geometrical configurations was designed based on dental crown and arch measurement data reported in previous studies. Ninety-six feature sizes can be directly measured on this original model with minimized manual measurement errors. Six types of photo-curing 3D printers, including Objet30 Pro using the Polyjet technique, Projet 3510 HD Plus using the Multijet technique, Perfactory DDP and DLP 800d using the DLP technique, Form2 and Form3 using the SLA technique, and each printer's respective 3D-printable dental model materials, were used to fabricate one set of physical models each. Regarding the feature sizes of the simulated dental crowns and dental arches, linear measurements were recorded. The scanned digital models were compared with the design data, and 3D form errors (including overall 3D deviation; flatness, parallelism, and perpendicularity errors) were measured. (3) Results: The lowest overall 3D deviation, flatness, parallelism, and perpendicularity errors were noted for the models printed using the Objet30 Pro (overall value: 45 μm), Form3 (0.061 ± 0.019 mm), Objet30 Pro (0.138 ± 0.068°), and Projet 3510 HD Plus (0.095 ± 0.070°), respectively. In color difference maps, different deformation patterns were observed in the printed models. The feature size proved most accurate for the Objet30 Pro fabricated models (occlusal plane error: 0.02 ± 0.36%, occlusogingival direction error: −0.06 ± 0.09%). (4) Conclusions: The authors investigated a novel evaluation approach for the spatial trueness of a 3D-printed dental model made of photopolymer resin based on a structurized dental model. This method can objectively and comprehensively evaluate the spatial trueness of 3D-printed dental models and has a good repeatability and generalizability.
polymer science