Effect of part deformation on performance of a rotary compressor using propane under high temperature

Jianhua Wu,Jiachen Li
DOI: https://doi.org/10.1016/j.applthermaleng.2021.117145
IF: 6.4
2021-07-01
Applied Thermal Engineering
Abstract:<p>The residential air conditioners using propane have advantages in hot climate regions due to its low discharge temperature and high performance. However, there is greater part deformation because of larger pressure difference and higher ambient temperature. The part deformation of rotary compressor has not been investigated completely about its main factor and the effect on performance. This paper simulated the temperature distribution and part deformation with finite element method, and proposed a calculation method of clearance variation based on the simulation results for performance research. The results indicated that thermal load has about ten times influence of the force load on deformation. The subsidence of the main bearing end face is the most severe deformation whose maximum value is 10 μm, and leads to a maximum reduction of 38% in related clearance. The leakage distribution is completely changed by part deformation, and the total amount is reduced by 14%. The correction of part deformation improves the accuracy of the performance simulation software, whose relative errors of volumetric efficiency and coefficient of performance (COP) reduce by 0.6% and 1.1% at most.</p>
energy & fuels,engineering, mechanical,thermodynamics,mechanics
What problem does this paper attempt to address?