Experimental Investigation on Off-Design Characteristics of R290 Rolling Piston Compressor
Yuande Dai,Jiantao Qiu,Xiangtao Han
DOI: https://doi.org/10.1007/s13369-021-06079-4
IF: 2.807
2021-08-23
Arabian Journal for Science and Engineering
Abstract:The test platform of R290 rolling piston compressor is established to study the variation of performance parameters under different conditions, including volumetric efficiency (ηV), coefficient of performance (COP), cooling capacity (Q), electric power (W), exhaust temperature (td), electrical efficiency (ηel), comprehensive efficiency coefficient (ηcom). With the increase in suction temperature (ts), COP increases by 8.3% partly due to the increase in td; ηV increases slowly in the range of 0.86–0.87 (mainly affected by temperature coefficient); ηel and ηcom increase by 3.2% and 5.6%, respectively. At variable compression ratio (π) conditions, with the decrease of Pe (VPe), COP decreases by over 25%, while with the increase of Pc (VPc), COP decreases by over 38%, which attributes to the different decline rates of W (decreasing slightly at VPe and increasing by over 30% at VPc); ηV decreases slowly (mainly affected by volume coefficient and temperature coefficient); ηel decreases with the increase of π; the decline rate of ηcom at VPc is 2–3 times that at VPe, which indicates that the frequent fluctuation of Pc will lead to the significant decrease of ηcom. This research provides experimental basis for the design and further improvement of R290 rolling piston compressor.
multidisciplinary sciences