A Novel Vapor Injection Structure on the Blade of A Rotary Compressor

Xingru Liu,Baolong Wang,Wenxing Shi,Penglei Zhang
DOI: https://doi.org/10.1016/j.applthermaleng.2016.02.098
IF: 6.4
2016-01-01
Applied Thermal Engineering
Abstract:Heat pumps with rotary compressors operating in low ambient temperature will face heavy performance degradation. A novel vapor injection structure on the blade for the rotary compressor has been proposed in this paper to overcome the back-flowing drawback of the traditional cylinder injection structure and increase the injection area. Based on a verified numerical model, the performance of a rotary compressor with the blade injection structure has been investigated. The results indicate that: the proposed vapor injection structure can eliminate the back-flowing of the injected refrigerant; compared to the traditional injection structure, the new structure can enhance the volumetric efficiency and mass flow-rate by 1.8-2.7% and 26.6-57.2%, respectively; and compared to the traditional injection structure, the new structure can increase the heating capacity and COP by 23.1-48.9% and 3.2-8.0%, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?