Continuous measurement of complex modulus from 10–30 kHz

Peter E. Madden,Timothy B. Totten
DOI: https://doi.org/10.1121/1.2023467
1986-05-01
The Journal of the Acoustical Society of America
Abstract:The paper describes a technique which measures the complex modulus of materials in the range 10–30 kHz. The apparatus measures the input impedance of a sample of the material which is approximately 0.25 in. long and 0.7 in. in diameter. A shaker with an impedance head is used to drive one end of the sample which has a large mass at the other end. A noise drive and analysis by a dual channel spectrum analyzer connected to a desktop computer, gives a continuous frequency spectrum of the real and imaginary parts of the modulus. The method has been used over a frequency range of 10–30 kHz to measure moduli from 107–1010 Pascals with loss factors as low as 0.02 and it is felt that these ranges could be extended. The technique enables a measurement over the complete frequency range to be made in less than 5 min and the results are repeatable.
acoustics,audiology & speech-language pathology