Extraction of negative hydrogen ions using a plasma electrode covered by Ta or Ti

K. Maeshiro,M. Wada,S. Masaki
DOI: https://doi.org/10.1063/5.0057430
2021-01-01
Abstract:We compared the effect of a tantalum (Ta) fresh coating with that of a Ta thin sheet covering the plasma electrode of a negative hydrogen ion source on the ratio of extracted negative hydrogen (H−) ion current to extracted electron current. Fresh Ta evaporation from a thin hot Ta filament showed about a 22 % increase of extracted H− ion current compared to the operation with a tungsten (W) hot filament. On the other hand, a thin Ta foil covering the plasma electrode decreased the extracted electron current without a large influence on H- ion current. Meanwhile, when a titanium (Ti) foil covered the plasma electrode, both the extracted H− ion current and electron current decreased substantially. With a plasma electrode bias higher than the plasma potential, the ratio of H- ion current to the electron current for the Ti covered plasma electrode exceeded 80%.
What problem does this paper attempt to address?