Announcing the 2008 Measurement Science and Technology Outstanding Paper Awards

John Foss,Richard Dewhurst,Kenichi Fujii,Paul Regtien
DOI: https://doi.org/10.1088/0957-0233/20/5/050101
IF: 2.398
2009-04-09
Measurement Science and Technology
Abstract:From 1991 to 2004, Measurement Science and Technology had awarded a Best Paper prize. The Editorial Board of this journal believed that such a prize was an opportunity to thank authors for submitting their work, and that it served as an integral part of the on-going quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the Editorial Board Members have presented 'Outstanding Paper Awards' in four subject categories: Measurement Science; Fluid Mechanics; Precision Measurements; and Sensors and Sensing Systems. 2008 Award Winners—Measurement Science Noise level estimation in weakly nonlinear slowly time-varying systems J R M Aerts, J Lataire, R Pintelon and J J J Dirckx Laboratory of Biomedical Physics, Universiteit Antwerpen, Groenenborgerlaan 171, 2020 Antwerp, Belgium and Department of Fundamental Electricity and Instrumentation (ELEC), Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium This paper [1] examines new methods to perform noise estimation in weakly nonlinear time-varying systems. In a clear presentation that describes the problem, the paper concentrates on weakly nonlinear phenomena in the acoustic regime. However, both the concepts and theory developed have wide applicability in other fields within measurement science wherever there is a time-varying nonlinear response. The theory uses two methods to estimate noise. The first is called the background frequency method, and the second is a periodic difference method. Both methods have their advantages, and disadvantages, which the authors highlight in a balanced account. They also spend some effort in validating the two approaches. Just as importantly, applications of the theory are presented as two experimental case histories. The first is a study of a vibrating membrane from a high quality microphone. This is an example of a time-invariant system, and the results show a frequency spectrum of the vibration velocity in the typical range of 2.0 kHz to 8.0 kHz. Secondly, as an example of a time-variant system, a membrane forming the middle ear of a gerbil is examined, in a similar frequency range. The paper shows that this time variation can be misinterpreted as an elevated noise floor, with the classical noise estimation method giving an incorrect result. In contrast, these new methods help to retrieve the correct noise information from experimental measurements, and to derive meaningful signal-to-noise ratios. Several features in the format of the article help to make this an excellent paper. Following an informative abstract, it has a concise introduction followed by a detailed formulation of the problem to be addressed. This helps to place the important theory of the paper into context in the next section—one in which an appendix is used for derivation of a useful algorithm. A following section has a detailed account of experiments that are used to demonstrate the effect of nonlinear time-varying systems. They show how the resultant noise measurements can be analysed using the paper's theory. A good range of velocity–frequency spectra are used to emphasize the concepts and techniques presented. The conclusions are concise, and the paper is rounded off with a solid reference list of some 20 papers describing related work, with most papers cited from 2004 onwards. This paper was rated as excellent by the external referees, and has been downloaded several hundred times since its publication. It is one of about 20 papers nominated this year for the best paper award in measurement science, and it gained the most votes from those shortlisted. With a generic appeal across the broad spectrum of measurement science, it also has potential relevance to applications in the life sciences. 2008 Award Winners—Fluid Mechanics Time-resolved entropy measurements using a fast response entropy probe Michel Mansour, Ndaona Chokani, Anestis I Kalfas and Reza S Abhari Laboratory for Energy Conversion, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland and Department of Mechanical Engineering, Aristotle University of Thessaloniki, Greece The paper [2] describes the development of a probe for measuring time-resolved entropy fluctuations. The technique was developed for use in turbomachinery applications where knowledge of the unsteady entropy in the wake of a rotating blade row can provide significant insight into the loss (dissipation) generation mechanisms. There is no direct method to measure entropy; hence the authors use an approach where the stagnation pressure and stagnation temperature are measured on the same probe. The stagnation, or 'total', pressure has been the subject of several of the authors' papers in the last few years. The more significant challenge was the time-resolved measurement of total temperature. The high Mach numbers present in the flows of interest lead to significant temperature gradients in the probe itself which contaminate this type of measurement. The paper describes a novel probe design along with a detailed heat transfer calculation and uncertainty analysis. The fluid mechanics members of the MST Editorial and Advisory Boards—T Fansler, J Foss, M Koochesfahani, I Marusic, S Morris, K Okamoto, F Scarano, E Tomita and M Wernet—considered all papers in the Fluid Mechanics section and the others that related to fluid mechanics. In the final analysis, the strengths of this paper strongly recommended it for the Award. 2008 Award Winners—Precision Measurement Self-calibration of divided circles on the basis of a prime factor algorithm R Probst Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, D-38116 Braunschweig, Germany This paper [3] describes a new method for the self-calibration of divided circles, which may be widely used for angle calibration of circular scales, precision polygons, indexing tables and angle encoders. In the field of angle metrology, two self-calibration methods have been proposed recently for high-precision angle encoders. One is called the equal-division-averaged (EDA) method proposed by Kajitani and Masuda in 1989, in which a divided circle of an angle encoder is compared to a second divided circle in several averaged distributions. The other method, proposed by Ernst in 1994, uses a divided circle with a dual exponential division number. Both methods are used for angle standards without any external reference. However, both also take a rather long time to complete a set of measurements. In this paper, the author proposed a new algorithm called the prime factor division (PFD) method based on the discrete Fourier transformation (DFT). This algorithm uses the circular division number N expressed as a product N = R × S, where the factors R and S are prime integer numbers. For the self-calibration of a divided circle, N difference measurements between R angle positions in a regular distribution and one reference angle position determined by S are evaluated by a two-dimensional DFT, yielding the N absolute division errors. The factor R is preferably chosen to be small, down to a minimum of R = 2, whereas the factor S may be as large as appropriate for the division number N of interest. In the case of a cross-calibration between two divided circles, the PFD method reduces the number of measurements from N2 to (R + 1) × N, resulting in a significant shortening of the time need for the cross-calibration between two divided circles. The author tested the new algorithm by calibrating a regular precision polygon and a gearwheel, and evaluated the performance by selecting the appropriate combinations of (R + 1)N difference measurements from a complete set of N2 cross-calibration measurements. He showed that the complex DFT algorithm is a key tool for the treatment of the division errors and the calibration of divided circles, especially by use of the PFD method. This paper was rated as excellent by the nomination committee members on precision measurement: Dr K Fujii (chairman), Prof. X Chen, Dr A Yacoot, Dr P Williams and Prof. Z Wei, in a strongly competitive list of 15 candidates, and has been downloaded several hundred times since its publication. Considering its impact on practical calibration for angle metrology and also its sophisticated idea on the algorithm, the paper was nominated for the MST Precision Measurement Award from the papers published in 2008. 2008 Award Winners—Sensors and Sensing Systems A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements Christopher R Dennison, Peter M Wild, David R Wilson and Peter A Cripton Department of Mechanical Engineering, University of Victoria, PO Box 3055, Victoria, British Columbia, V8W 3P6, Canada, Division of Orthopaedic Engineering Research, Department of Orthopaedics University of British Columbia, Canada and Department of Mechanical Engineering, University of British Columbia, Canada A major cause of back pain is the degeneration of intervertebral discs (IVDs). The pressure distribution in IVDs appears to be a good indicator of the degeneration state. To measure this pressure a very small sensor is required. The authors of this paper [4] have developed such a sensor, based on an in-fibre Bragg grating (FBG). Compared to a bare fibre, this sensor has a substantially higher sensitivity, and compared to the currently used strain gauge sensors the new sensor has much smaller dimensions, allowing in vivo pressure measurement. The paper starts with a clear introduction in which the problem of present IVD pressure sensors is described and the need for smaller sensors is motivated. In subsequent sections the construction of the probe is described in detail, and a finite-element model is used to predict the sensor behaviour. Experimental results are reported in detail, including uncertainty margins. Comparative experiments between the strain gauge based sensors and the new FBG sensor are presented as well, demonstrating the superiority of the latter. The paper received high quality ratings by the reviewers, and the appreciation by the readers of MST is confirmed by a high number of downloads. The reduction of sensor diameter (from a few mm down to 400 μm) and the higher flexibility are important features of this application. The use of a silicone sealant in a steel hypodermic tube around the fibre, resulting in a higher sensitivity compared to a bare fibre, is a significant achievement of this research. Its sensitivity can further be increased by a reduction of the fibre diameter: this is the subject of another excellent article [5] by the authors, which appeared in the December issue of 2008. The Outstanding Paper Awards, comprising a cash honorarium and certificate, will be presented to the authors of the winning papers at suitable venues in the near future. The Editorial Board would like to congratulate the winning authors and would like to encourage all researchers to think of Measurement Science and Technology as the home for your best submissions. References [1] Aerts J R M, Lataire J, Pintelon R and Dirckx J J J 2008 Noise level estimation in weakly nonlinear slowly time-varying systems Meas. Sci. Technol. 19 105101 (14pp) [2] Mansour M, Chokani N, Kalfas A I and Abhari R S 2008 Time-resolved entropy measurements using a fast response entropy probe Meas. Sci. Technol. 19 115401 (10pp) [3] Probst R 2008 Self-calibration of divided circles on the basis of a prime factor algorithm Meas. Sci. Technol. 19 015101 (11pp) [4] Dennison C R, Wild P M, Wilson D R and Cripton P A 2008 A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements Meas. Sci. Technol. 19 085201 (12pp) [5] Dennison C R and Wild P M 2008 Enhanced sensitivity of an in-fibre Bragg grating pressure sensor achieved through fibre diameter reduction Meas. Sci. Technol. 19 125301 (11pp)
engineering, multidisciplinary,instruments & instrumentation
What problem does this paper attempt to address?