Announcing the 2013 Measurement Science and Technology Outstanding Paper Awards

John Foss,Richard Dewhurst,Andrew Yacoot,Srinivas Tadigadapa,Kara Peters
DOI: https://doi.org/10.1088/0957-0233/25/7/070201
IF: 2.398
2014-06-06
Measurement Science and Technology
Abstract:Since 1991, Measurement Science and Technology has awarded a Best Paper prize. The Editorial Board of this journal believe that such a prize is an opportunity to thank authors for submitting their work, and serves as an integral part of the on-going quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the Editorial Board have presented 'Outstanding Paper Awards'. This year awards were presented in the areas of Fluid Mechanics, Measurement Science, Precision Measurement, Sensors and Sensing Systems, and Optical and Laser-based Techniques. Although the categories mirror subject sections in the journal, the Editorial Board consider articles from all categories in the selection process. 2013 Award Winner—Fluid Mechanics Extraction of skin-friction fields from surface flow visualizations Tianshu Liu Department of Mechanical and Aerospace Engineering, Western Michigan University, Kalamazoo, MI 49008, USA The skin friction or wall shear stress, τ w, for a wall bounded turbulent flow is a quantity of fundamental importance. It is the basis for the wall unit, ν/u τ (kinematic viscosity/friction velocity: [τ w/ρ ]1/2), which establishes the intrinsic length scale in the flow. The selected paper [1] provides a comprehensive review of—and builds upon—prior techniques to obtain τ w values over an area of interest for flow past complex geometries. The quantities that can be measured by optical imaging are shown to be related to the skin friction by the optical flow equation, which in turn is solved numerically as an inverse problem via the variational approach. The paper provides a well defined set of guidelines for other investigators. Detailed examples of skin-friction measurements using luminescent oil films as well as temperature- and pressure-sensitive paints are presented. Quantitative uncertainty estimates are included in the paper. Given the importance of the wall shear stress (skin friction) in fluid mechanics and the notorious difficulty of measuring this quantity directly, this paper is expected to be a seminal contribution. The paper was one of four in the special feature on Wall Shear Stress organized by Professor A Naguib in the December 2013 issue. 2013 Award Winner—Measurement Science Analysis of calibration-free wavelength-scanned wavelength modulation spectroscopy for practical gas sensing using tunable diode lasers K Sun, X Chao, R Sur, C S Goldenstein, J B Jeffries and R K Hanson High Temperature Gasdynamics Laboratory, Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA In the previous two years, the Measurement Science Award has gone to important papers in diagnostic fields, namely particle image velocimetry (PIV [2]) and x-ray micro-computed tomographic systems [3]. This year's award [4] goes to another diagnostic field, infrared spectroscopy for practical gas sensing. Infrared spectroscopy is a very important topic for measurement science, concerned with the monitoring of gases in our environment. Over two decades, this form of spectroscopy has been enabled with the development of tunable diode lasers (TDLs). Hence, tunable diode laser absorption spectroscopy (TDLAS) is now an established method for in situ measurements of gas composition, temperature, pressure and velocity. Gases such as ammonia, methane, carbon dioxide and monoxide, hydrogen chloride, hydrogen fluoride and sulfur dioxide can all be monitored by commercially available systems. Some advances have been associated with improvements in infrared detectors or in the properties of some diode lasers. For homogeneous gases, the interpretation using the Beer–Lambert law and direct absorption (DA) is quite straightforward. DA is the preferred method when an absorption line can be found in the infrared region with an isolated transition of sufficient strength, and with a linewidth small enough to allow the laser to be wavelength-scanned on the absorption line, and just off it (as a reference baseline). Otherwise, wavelength modulation spectroscopy (WMS) is used for those cases where the gas offers small absorbance, or high pressure or for absorbers with closely spaced transitions, which are blended in the wings precluding measurement of a non-absorbing baseline. WMS is a powerful technique, but the interpretation is more complex, and the authors explain in their introduction the strategies that are normally adopted for data interpretation. In this new paper, the authors explain a new strategy for wavelength modulation spectroscopy. The strategy is different in two significant ways. Firstly, the measured laser intensity is used to simulate the transmitted laser intensity. Secondly, digital lock-in and low-pass filter software is used to expand both simulated and measured transmitted laser intensities into harmonics of the modulation frequency. In this way, the analysis scheme does not require an isolated transition; instead it recovers the lineshape for absorption from unresolved blended transitions. The paper goes on to describe an example using this novel method. It discusses the analysis of WMS absorption detection using water as an example. The advantages of the new method are explained, and a comparison is made with the more usual Fourier analysis approach. This paper is excellent in its clarity, presentation and scientific description. Issues have been clearly identified, and a new method of analysis has been presented with some evidence of validation. Its conclusions contain an in-depth summary, and the following 42 references are informative and representative of what is a very large field of study. It was voted as the best paper from a shortlist of 12 nominated papers. 2013 Award Winner—Precision Measurement Interferometric diameter determination of a silicon sphere using a traceable single laser frequency synthesizer Xuejian Wu, Yan Li, Haoyun Wei, Honglei Yang, Guoce Yang and Jitao Zhang State Key Lab of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, People's Republic of China This paper [5] describes the determination of the absolute diameter of a silicon sphere for the Avogadro project using a phase shifting interferometer based on a flat etalon. The absolute diameter is attained by combining the fractional and integral measurement results, which are measured with phase shifting interferometry and frequency sweeping interferometry using laser frequency tuning, respectively. An optical frequency comb is used as the frequency ruler to measure and control the frequency of an external cavity diode laser in order to reduce the uncertainty contribution from the laser frequency on the phase steps to an insignificant level. The Carré algorithm with arbitrary but equal phase steps is used to calculate the fractional interference phases according to the characteristic of single laser frequency synthesiser. The paper provides a comprehensive description of the measurement techniques together with an uncertainty budget for the measurement of a silicon sphere. An overall measurement uncertainty of 5 nm is achieved. This paper has been downloaded more than 130 times since its publication. The selection committee members on the Precision Measurement Award, Dr A Yacoot, Dr P Williams, Dr H Bosse, Professor X Chen and Dr T Eom, selected this paper from a strongly competitive list of several candidates. Considering its impact on accurate evaluation of the measurement of silicon spheres, the paper was selected as the winner of the Precision Measurement Award for 2013. 2013 Award Winner—Sensors and Sensing Systems Enhancing the dynamic range of ultrasound imaging velocimetry using interleaved imaging C Poelma1 and K H Fraser 2 1Laboratory for Aero and Hydrodynamics (3ME-P&E), Delft University of Technology, Leeghwaterstraat 21, 2628 CA Delft, The Netherlands 2Department of Bioengineering, Imperial College London, South Kensington Campus, SW7 2AZ London, UK This paper [6] presents an innovative interleaved imaging technique to overcome the dynamic velocity range limitation of current ultrasound imaging velocimetry. Due to the nature of the recording of ultrasound images, the conversion from pixel displacement to velocities is less straightforward since the lines of an image are not recorded at the same time, so the inter-frame time needs to be corrected for any displacement. The upper limit of displacement velocities is widely reported in the literature as a major problem with the best measured in-vivo flow rates of ~ 70–80 cm s−1 or by restricting the field of view to as high as 140 cm s−1. In this study, the authors introduce a novel imaging method that enhances the dynamic range of ultrasound imaging velocimetry by an interleaved read-out approach. Using this technique, the inter-frame time is no longer fixed to the imaging rate and allows for the displacement of fast flows to be reduced by choosing an appropriate image offset parameter. The authors show that this technique allows for measurement of flows of up to 140 cm s−1 with the maximum lateral field of view and unrestricted depth. In their winning paper the authors have very clearly articulated the dynamic range limitations of the flow measurement using ultrasound imaging velocimetry and have very elegantly described the theory and experimental implementation of the interleaved imaging technique. The superior performance of the proposed method is clearly demonstrated through experimental results and images analyzed using the necessary mathematical transforms. The improved dynamic flow rate measurements using ultrasound imaging velocimetry made feasible using this technique are likely to have a significant impact on non-invasive blood flow monitoring for clinical screening and post-operative monitoring. 2013 Award Winner—Optical and Laser-based Techniques Detection of excited level population transfer in an MOT through the measurement of trapped atom number. L Moi1, G Batignani1, A Khanbekyan1, K Khanbekyan1, C Marinelli1, E Mariotti1, L Marmugi1, L Corradi2, A Dainelli2, R Calabrese3, G Mazzocca3, L Tomassetti3 and P Minguzzi4 1CNISM, Physics Department, University of Siena, via Roma 56, 53100 Siena, Italy 2INFN—Laboratori Nazionali di Legnaro, viale dell'Università 2, 35020 Legnaro (PD), Italy 3University of Ferrara and INFN, via Saragat 1, 44122 Ferrara, Italy 4CNISM, Physics Department, University of Pisa, largo Pontecorvo 3, 56127 Pisa, Italy The selected paper [7] applies a direct fluorescence detection scheme to monitor the very low number of trapped atoms, simulating the conditions in a francium magneto-optical trap (MOT). Precise atomic parity nonconservation measurements are inherently difficult due to the fact that extremely weak signals must be detected. By scanning a probe beam across a resonance condition and then detecting the MOT fluorescence, the authors were able to monitor the population transfer from the ground level and the first excited level in the MOT. The significance of this work is that it presents a rapid and flexible method to detect the number of trapped atoms in conditions where very low numbers of these atoms are present. Such high precision measurements are essential in nuclear physics and are fundamental to our understanding of nuclear decay processes. We have selected this article for the Best Paper Award because the measurement technique demonstrated is not only innovative, but also flexible to implement as it is wavelength independent and presents a high signal to noise ratio. The experimental configuration was also extremely well documented in the paper, including a detailed estimate of the detection limits. Data were presented for many different excitation mechanisms to show the wide applicability of the measurement technique. It is expected that this innovative measurement strategy will be seen in successful applications of the study of atomic parity nonconservation in different nuclear particles in the near future. The chairmen would like to thank the authors for choosing to publish their work in Measurement Science and Technology , and hope that other researchers enjoy reading these works and feel encouraged to submit their own best work to the journal. References [1] Liu T 2013 Extraction of skin-friction fields from surface flow visualizations as an inverse problem Meas. Sci. Technol 24 124004 [2] Oishi M, Kinoshita H, Fujii T and Oshima M 2011 Simultaneous measurement of internal and surrounding flows of a moving droplet using multicolour confocal micro-particle image velocimetry micro-PIV Meas. Sci. Technol. 22 105401 [3] Hiller J, Maisl M and Reindl L M 2012 Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications Meas. Sci. Technol 23 085404 [4] Sun K, Chao X, Sur R, Goldenstein C S, Jeffries J B and Hanson R K 2013 Analysis of calibration-free wavelength-scanned wavelength modulation spectroscopy for practical gas sensing using tunable diode lasers Meas. Sci. Technol 24 125203 [5] Wu X et al 2013 Interferometric diameter determination of a silicon sphere using a traceable single laser frequency synthesizer Meas. Sci. Technol. 24 115202 [6] Poelma C and Fraser K H 2013 Enhancing the dynamic range of ultrasound imaging velocimetry using interleaved imaging Meas. Sci. Technol. 24 115701 [7] Moi L et al 2013 Detection of excited level population transfer in an MOT through the measurement of trapped atom number Meas. Sci. Technol. 24 015201
engineering, multidisciplinary,instruments & instrumentation
What problem does this paper attempt to address?