Enhanced antibacterial activity of Ti-Cu alloy by selective acid etching

Ming Lu,Ziming Zhang,Jiaqi Zhang,Xiaoyan Wang,Gaowu Qin,Erlin Zhang
DOI: https://doi.org/10.1016/j.surfcoat.2021.127478
IF: 4.865
2021-09-01
Surface and Coatings Technology
Abstract:<p>Titanium‑copper (TiCu) alloys showed potential application in clinical field due to their excellent antibacterial properties. A selective acid etching (SAE) was applied to TiCu alloy in order to further improve the antibacterial properties. The phase constitute and the surface microstructure were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS), the corrosion properties and Cu ion release behavior were measured by electrochemical testing and inductively coupled plasma spectrometry (ICP), the antibacterial property was assessed by a plate-count method and the cell compatibility was evaluated by CCK-8 test. It was shown that more Ti<sub>2</sub>Cu particles were exposed on the surface of TiCu sample after SAE treatment, which increased the corrosion current density and accelerated the Cu ion release due to the galvanic corrosion between Ti-Ti<sub>2</sub>Cu couple. The plate counting results demonstrated that the antibacterial ability of TiCu alloy was significantly enhanced from 79% to &gt;99.9% by SAE treatment due to the multifunction of increased Ti<sub>2</sub>Cu phase on the surface, Cu ion release and the formation of Cu<sub>2</sub>O. Besides, no cytotoxicity was detected to MC3T3-E1 cells on all test samples.</p>
physics, applied,materials science, coatings & films
What problem does this paper attempt to address?