Pilot-scale corrosion tests of high chlorine coal using novel resistance probes

I. Wright,R. Clarkson,L. Monroe
1994-12-31
Abstract:Corrosion rates of simulated water-wall surfaces and superheater tubes were measured during pilot-scale combustion of a high chlorine coal in the Southern Company and Southern Research Inst. combustion Research Facility. Novel probes from Rowan Technologies of the United Kingdom were used that measure surface corrosion by changes in the probe`s electrical resistance. Conventional corrosion coupons were also used in the superheater section of the furnace. A baseline test of a low chlorine coal was used as a comparison case, in order to make relative predictions for performance in full-scale boilers. Overfire air was used during the combustion test, where water-wall probes were inserted above and below the overfire air injection point, which allowed measurements of corrosion rates under oxidizing and near-reducing conditions.
Environmental Science,Chemistry,Engineering,Materials Science