Assessment of Perfusion Volumes by a New Automated Software for Computed Tomography Perfusion

Zhixin Cao,David Wang,Xueyan Feng,Pengfei Yang,Hao Wang,Ziqi Xu,Yahui Hao,Wanxing Ye,Fengwei Chen,Liyuan Wang,Manjun Hao,Na Wu,Kai-Xuan Yang,Yunyun Xiong,Yongjun Wang
DOI: https://doi.org/10.1136/svn-2023-002964
IF: 5.9
2024-03-28
Stroke and Vascular Neurology
Abstract:Introduction To compare the perfusion volumes assessed by a new automated CT perfusion (CTP) software iStroke with the circular singular value decomposition software RAPID and determine its predictive value for functional outcome in patients with acute ischaemic stroke (AIS) who underwent endovascular treatment (EVT). Methods Data on patients with AIS were collected from four hospitals in China. All patients received CTP followed by EVT with complete recanalisation within 24 hours of symptom onset. We evaluated the agreement of CTP measures between the two softwares by Spearman’s rank correlation tests and kappa tests. Bland-Altman plots were used to evaluate the agreement of infarct core volume (ICV) on CTP and ground truth on diffusion-weighted imaging (DWI). Logistic regression models were used to test the association between ICV on these two softwares and functional outcomes. Results Among 326 patients, 228 had DWI examinations and 40 of them had infarct volume >70 mL. In all patients, the infarct core and hypoperfusion volumes on iStroke had a strong correlation with those on RAPID (ρ=0.68 and 0.66, respectively). The agreement of large infarct core (volume >70 mL) was substantial (kappa=0.73, p<0.001) between these two softwares. The ICV measured by iStroke and RAPID was significantly correlated with independent functional outcome at 90 days (p=0.009 and p 70 mL, the ICV of iStroke and RAPID was comparable on individual agreement with ground truth. Conclusion The automatic CTP software iStroke is a reliable tool for assessing infarct core and mismatch volumes, making it clinically useful for selecting patients with AIS for acute reperfusion therapy in the extended time window.
clinical neurology
What problem does this paper attempt to address?
The paper aims to address the issue of evaluating the effectiveness of a new automated CT perfusion (CTP) software, iStroke, in patients with acute ischemic stroke (AIS), particularly its accuracy in assessing infarct core volume (ICV) and hypoperfusion volume, and comparing it with the existing standard software, RAPID. Specifically, the study aims to: 1. **Compare the performance of iStroke and RAPID on CTP images**: Evaluate the correlation and consistency between iStroke and RAPID in measuring ICV and hypoperfusion volume. 2. **Validate the clinical predictive value of iStroke**: Determine whether the ICV assessed by iStroke can effectively predict the functional outcomes of AIS patients after receiving endovascular treatment (EVT). 3. **Assess the consistency of iStroke with the true values**: Verify the accuracy of the ICV assessed by iStroke by comparing it with the true values from diffusion-weighted imaging (DWI). Through these objectives, the study hopes to demonstrate that iStroke is a reliable tool that can be used to select AIS patients suitable for acute reperfusion therapy, especially within an extended time window.