A Comparative Study of Transcranial Color-Coded Doppler (TCCD) and Transcranial Doppler (TCD) Ultrasonography Techniques in Assessing the Intracranial Cerebral Arteries Haemodynamics

Simon Takadiyi Gunda,Tsam Kit Veronica Ng,Tsz-Ying Liu,Ziman Chen,Xinyang Han,Xiangyan Chen,Marco Yiu-Chung Pang,Michael Tin-Cheung Ying
DOI: https://doi.org/10.3390/diagnostics14040387
IF: 3.6
2024-02-11
Diagnostics
Abstract:Cerebrovascular disease (CVD) poses a major public health and socio-economic burden worldwide due to its high morbidity and mortality rates. Accurate assessment of cerebral arteries' haemodynamic plays a crucial role in the diagnosis and treatment management of CVD. The study compared a non-imaging transcranial Doppler ultrasound (TCD) and transcranial color-coded Doppler ultrasound (with (cTCCD) and without (ncTCCD)) angle correction in quantifying middle cerebral arteries (MCAs) haemodynamic parameters. A cross-sectional study involving 50 healthy adults aged ≥ 18 years was conducted. The bilateral MCAs were insonated via three trans-temporal windows (TTWs—anterior, middle, and posterior) using TCD, cTCCD, and ncTCCD techniques. The MCA peak systolic velocity (PSV) and mean flow velocity (MFV) were recorded at proximal and distal imaging depths that could be visualised on TCCD with a detectable spectral waveform. A total of 152 measurements were recorded in 41 (82%) subjects with at least one-sided open TTW across the three techniques. The mean PSVs measured using TCD, ncTCCD, and cTCCD were 83 ± 18 cm/s, 81 ± 19 cm/s, and 93 ± 21 cm/s, respectively. There was no significant difference in PSV between TCD and ncTCCD (bias = 2 cm/s, p = 1.000), whereas cTCCD yielded a significantly higher PSV than TCD and ncTCCD (bias = −10 cm/s, p < 0.001; bias = −12 cm/s, p ≤ 0.001, respectively). The bias in MFV between TCD and ncTCCD techniques was (bias = −0.5 cm/s; p = 1.000), whereas cTCCD demonstrated a higher MFV compared to TCD and ncTCCD (bias = −8 cm/s, p < 0.001; bias = −8 cm/s, p ≤ 0.001, respectively). TCCD is a practically applicable imaging technique in assessing MCA blood flow velocities. cTCCD is more accurate and tends to give higher MCA blood flow velocities than non-imaging TCD and ncTCCD techniques. ncTCCD is comparable to non-imaging TCD and should be considered in clinical cases where using both TCD and TCCD measurements is needed.
medicine, general & internal
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to compare the differences between transcranial Doppler ultrasound (TCD) and transcranial color - coded Doppler ultrasound (TCCD, including angle - corrected cTCCD and non - angle - corrected ncTCCD) in evaluating the hemodynamic parameters of the middle cerebral artery (MCA). Specifically, the study aims to: 1. **Evaluate the accuracy of different techniques**: By comparing the differences among the three techniques of TCD, ncTCCD and cTCCD in measuring the peak systolic velocity (PSV) and mean flow velocity (MFV) of the middle cerebral artery, determine which technique is more accurate. 2. **Explore the influence of angle correction**: Study whether angle - corrected cTCCD can provide different hemodynamic measurement results from non - angle - corrected ncTCCD and non - imaging TCD. 3. **Verify the comparability between techniques**: Use statistical methods such as Bland - Altman plots to evaluate the measurement consistency among these techniques to determine their interchangeability in clinical applications. ### Research background Cerebrovascular diseases (CVD) are an important global public health and socio - economic burden. Their high incidence and mortality make accurate assessment of cerebral artery hemodynamics crucial. Although traditional digital subtraction angiography (DSA) is precise, it is limited by its invasiveness and high cost. In contrast, TCD and TCCD are non - invasive and portable imaging techniques that can be used to evaluate cerebral artery hemodynamics. However, TCD cannot accurately locate blood vessels, while TCCD combines B - mode and color Doppler imaging and can more accurately identify blood vessels and perform blood flow measurements. ### Research hypothesis The study hypothesizes that TCCD with angle correction (cTCCD) will provide different hemodynamic measurement results from non - imaging TCD and TCCD without angle correction (ncTCCD), and cTCCD may be more accurate. Through this study, the author hopes to provide a scientific basis for selecting appropriate ultrasound techniques in clinical practice, thereby improving the diagnosis and treatment management of cerebrovascular diseases.