Transcranial Color-Coded Sonography Criteria for Moderate and Severe Middle Cerebral Artery Stenosis

Ran Liu,Jingzhi Li,Yang Hua,Jie Yang,Yue Zhao,Xiaojie Tian,Yan Ma,Wenbo Zhao
DOI: https://doi.org/10.1016/j.ultrasmedbio.2020.09.008
2021-01-01
Abstract:<p>This study aimed to establish optimal criteria for evaluation of moderate (50%–69%) and severe (70%–99%) middle cerebral artery (MCA) stenosis with transcranial color-coded sonography (TCCS). A total of 375 cases provided 409 TCCS/digital subtraction angiography vessel pairs. Peak systolic velocity (PSV), end-diastolic velocity (EDV) and mean flow velocity (MFV) of the MCA were measured. The stenotic/distal MFV ratios (SDRs) were calculated. With digital subtraction angiography as a reference, for 50%–69% MCA stenosis, the optimal combined criteria were PSV ≥180 cm/s (sensitivity 95.7%, specificity 64.9% and overall accuracy 69.7%); EDV ≥75 cm/s (90.0%, 66.4% and 68.7%); MFV ≥110 cm/s (95.7%, 64.0% and 69.4%); and SDR ≥2.5 (88.6%, 71.3% and 76.3%). Criteria for 70%–99% MCA stenosis were PSV ≥240 cm/s (93.5%, 89.9% and 85.5%); EDV ≥100 cm/s (96.8%, 89.0% and 87.3%); MFV≥160 cm/s (91.9%, 92.8% and 92.2%); and SDR ≥4 (87.1%, 92.2% and 91.4%). Parameters of the MCA detected by TCCS, especially SDR, may increase accuracy in diagnosis of 50%–69% and 70%–99% MCA stenosis.</p>
radiology, nuclear medicine & medical imaging,acoustics