The Effect Spray Testing Condition on the Corrosion Performance of Hydrothermally Sealed Anodic Oxide on a 5005 Aluminum Alloy: Comparison between Neutral Salt Spray, Acetic Salt Spray and Prohesion Testing Methods

Tambi Ramdé,Michele Fedel,Stefano Rossi
DOI: https://doi.org/10.1149/1945-7111/ad367c
IF: 3.9
2024-03-22
Journal of The Electrochemical Society
Abstract:In this work, the output of different accelerated tests on anodic aluminum oxide (AAO) coatings developed on AA5005 aluminum alloy (sulfuric acid bath and hydrothermal sealing) has been investigated. In particular, three corrosion testing methods, namely neutral salt spray test (NSS), acetic acid salt spray (AASS) and prohesion test, have been performed on the sealed AAO-coated panels in order to investigate the reliability of the obtained results to the electrochemical impedance ones. NSS and prohesion testing results are found to align with findings from electrochemical impedance spectroscopy (EIS). The acetic salt spray test proved highly corrosive, causing rapid depletion of the oxide layer's protective capabilities, as indicated by the EIS analysis. These results seem to be underestimated by optical image analysis.
electrochemistry,materials science, coatings & films
What problem does this paper attempt to address?