Abstract:The in situ preparation of high-temperature strain sensors and minimization of the monitoring of the surface impact are crucial for effectively monitoring the health of devices in high-temperature and extreme environments, such as aircraft engines. However, most high-temperature strain gauges are expensive and complex to manufacture, and they exhibit poor high-temperature stability. In this study, polymer-derived ceramic (PDC) technology is introduced to prepare polymer-derived ceramic thin-film strain gauges (TFSGs). The high-temperature stability of the sensor is improved by the superior high-temperature and adhesion performance characteristics of polymer-derived ceramics. Additionally, SiO2 is generated at high temperatures to create a protective film layer. Herein, we present the fabrication of PDC/indium tin oxide (ITO) thin-film strain gauges using direct ink writing (DIW) three-dimensional (3D) printing to assess their performance. The experimental results demonstrate that the prepared PDC/ITO thin-film strain gauges have a low resistance drift rate of 0.55% per hour and a high strain coefficient of 8 at 1100 °C after one hour of heat preservation. These gauges have a stable structure at 1200 °C and should withstand temperatures of at least 1400 °C in the short term.