Model Predictive Coordinated Control Method for Non-Uniform Indoor Temperature Environment with VAV System

Yuming Li,Yiqun Pan,Zhizhong Huang,Ling Fu,Jing Li,Tianrui Sun,Mingya Zhu
DOI: https://doi.org/10.26868/25222708.2023.1677
2023-01-01
Abstract:In the control of Variable Air Volume (VAV) terminals in traditional VAV system, the temperature of one thermostat is used to represent the room temperature. The monitering by only one thermostat on the zonal ambient temperature has weakened the holistic effect of HVAC control system due that the one thermostat cannot accurately reflect the temperature of each zone, which caused the HVAC control hardly satisfies the dynamically changing and varying demands from different thermal zones. For a large open office having multiple thermal zones, if we can install multiple thermostats, then the occupants are able to adjust the ambient temperature according to their personal comfort. In this case, the real indoor temperature distribution can be collected and fed back to the VAV control system. With the traditional single-input single-output(SISO) feedback control algorithm, if the monitered temperature of one thermostat is different from its setpoint, only the corresponding VAV terminal adjusts the air flowrate, this will affect the control effect of surrounding thermostats. Thus, the traditional SISO feedback control algorithm needs great improvements to meet diverse temperature preference and non-uniform temperature distribution for multiple thermal zones supplied by a VAV system, with the consideration of mutual influence of airflow from each VAV terminal.For the common situation of a large open office with multiple VAV terminals, this paper proposes an open-loop air flowrate predictive coordinated control method based on MATLAB-Simulink platform based on collected operation data. A closed-loop Model Predictive Control(MPC) correction system is proposed and combined to the air flowrate predictive coordinated control system. All thermostats and diffusers are connected in one control system. The air flowrate of each diffuser is coordinated supplied according to the diverse temperature preference. The accuracy of complete control system is validated with 500 random cases. The results show that the model predictive coordinated control system with correction can sufficiently satisfy different setpoint preferences under the dynamic changing of the non-uniform temperature environment. The quantile 10% of control error percentage is -2.68% while the quantile 90% of control error percentage is 2.26%, and the temperature control error of each thermostat is within -1℃~1℃.
What problem does this paper attempt to address?