Quantitative Analysis for Effect of Hydrodynamic Factors on Erosion—Corrosion of Air Cooler

Zhijun Dai
2007-01-01
Abstract:For the leakage of high pressure air cooler tubes caused by corrosion,relationsbip between hydrodynamic factors and erosion-corrosion of high pressure air cooler tubes in the hydrocracking unit of a petrochemical corporation was discussed. Accelerating effect of hydrodynamic factors such as turbulence intensity and shear stress acting on inner wall of air cooler tubes on corrosion were quantitatively investigated by a weight loss test method.The position badly destroyed by erosion-corrosion was found.Erosion-corrosion rate of high pressure air cooler tubes was predicted according to experimental data and CFD simulation results.
What problem does this paper attempt to address?