Image motion and experimental study of a 0.1′′ space pointing measuring instrument for micro-vibration conditions
LI Lin,YUAN Li,WANG Li,WANG Miaomiao,GONG Xiaoxue,SUI Jie,WU Yanpeng,Ran ZHENG,Lin LI,Li YUAN,Li WANG,Miaomiao WANG,Xiaoxue GONG,Jie SUI,Yanpeng WU
DOI: https://doi.org/10.1016/j.cja.2022.02.003
IF: 5.7
2022-02-01
Chinese Journal of Aeronautics
Abstract:There exists an increasing need for Milli-Arc-Seconds (MAS) accuracy pointing measurement for current and future space systems. To meet the 0 . 1 ″ space pointing measurement accuracy requirements of spacecraft in future, the influence of spacecraft micro-vibration on a 0 . 1 ″ Space Pointing Measuring Instrument (SPMI) is studied. A Quasi-Zero Stiffness Device (QZSD) with adaptive adjustment and variable stroke was proposed. Then, a series of micro-vibration experiments of the SPMI were carried out. The influence of the micro-vibration generated by Guidance Navigation Control (GNC) attitude control components under different attitudes on the SPMI was analyzed. Point spread function of image motion in micro-vibration was also derived. Further, the changes of image motion under the micro-vibration environment were evaluated by extracting the gray centroid of the images, and the experiment processes and results are deeply discussed. The results show that the first-order frequency of the QZSD system is 0.114 Hz, and it is induced by a double pendulum system; the image motion of single flywheel spinning reached 0.015 pixels; whilst the image motion reached 0.03 pixels when three flywheels are combined spinning. These latest findings provide a beneficial theoretical and technical support for the development of spacecraft with 0 . 1 ″ pointing accuracy.
engineering, aerospace