10W@80K High Frequency Pulse Tube Cryocooler

Enchun Xing,Qingjun Tang,H. L. Chen,Yonghui Ma,Tianshi Feng,Y. Liu,Nailiang Wang,Jinghui Cai
2023-01-01
Abstract:For the space infrared detectors, there are high requirements for the volume and weight of the pulse tube cryocooler. However, the volume and weight of the pulse tube cryocooler with a cooling capacity of 10 W at the temperature range of 80 K to 120 K are relatively large nowadays. Thus, it is formidable to meet the needs of future space applications. Previous research demonstrates that the lightweight of the pulse tube cryocooler can be achieved by increasing the operating frequency of the cryocooler. Moreover, the efficiency of pulse tube cryocoolers used in the liquid nitrogen temperature can be improved by increasing the charging pressure and applying regenerator packing with a smaller hydraulic diameter. The effects of regenerator length, charge pressure, and regenerator packing on pulse tube cryocoolers are first analyzed in the paper. The cold fingers for pulse tube cryocooler with a length of 35 mm and a cold finger diameter of 20 mm are designed. A lightweight pulse tube cryocooler with a total mass of 2.7 kg and an operating frequency of 126 Hz is obtained by optimizing the factors affecting the efficiency of the cryocooler, such as the phase shifter and the charging pressure. The cooling capacity of 10 W can be obtained at 80 K when the electric power input is 250 W, and the relative Carnot efficiency of the pulse tube cryocooler is 10.9%.
What problem does this paper attempt to address?