Pulse Tube Cryocooler Operating Performance above Hundred Herz for THz Detectors

Gan Zhihua,Qiu Limin
2008-01-01
Rare Metal Materials and Engineering
Abstract:The improvement of THz technology requires more compact and higher efficient refrigeration system. Recent study indicates that a cryocooler could operate at very high frequency required charging a higher pressure and smaller regenerator volumes that could still keep a relative high efficiency. Such size reductions are particularly important for THz technology as well as space applications and for the development of microcryocoolers for MEMS applications. Based on REGEN calculations, we study an efficient operation of a pulse tube cryocooler at 120 Hz with an average pressure of 3.5 MPa. A no-load temperature of 50.0 K was achieved. This is the first time such low temperatures have been achieved for operating frequencies above 100 Hz. The net refrigeration power at 80 K was 2 W when the pressure ratio at aftercooler was 1.30. The cryocooler cooled from room temperature to 80 K in 7 min. The fast cooldown time is a result of the small regenerator volume used for high frequency operation.
What problem does this paper attempt to address?