Essential Improvement of the JT Cryocooler Working at Liquid Helium Temperature for Space: Efficient and Lightweight

Zhichao Chen,Shaoshuai Liu,Xinquan Sha,Yunwei Shen,Wang Yin,Zheng Huang,Lei Ding,Zhenhua Jiang,Zhihua Gan,Yinong Wu
DOI: https://doi.org/10.1016/j.ijrefrig.2024.08.006
IF: 4.14
2024-01-01
International Journal of Refrigeration
Abstract:Due to long lifetime, low level vibration and negligible electromagnetic interference, the Joule-Thomson (JT) cryocooler working at liquid helium temperature has been used in space. However, its cooling capacity and thermodynamic efficiency still need to be further improved under a certain mass limit, which is an essential improvement for space-efficient application of the JT cryocooler. Therefore, in this study, optimization design is carried out for a JT cryocooler working at liquid helium temperature. Based on the modification of Stirling cryocooler, pulse tube cryocooler and JT compressor, the developed JT cryocooler can provide a cooling capacity of 0.36 W at 4.18 K while the total input power and the total mass (without cryostat) are 1157 W and 26.8 kg, respectively. Compared with the literature research, it can be found that the developed JT cryocooler is suitable for space applications.
What problem does this paper attempt to address?