DISCUSSIONS ON THE ROBUSTNESS OF STEEL CONNECTIONS IN FIRE

Huimin Yu
2011-01-01
Abstract:The behaviour differences between connections and elevated temperatures and the corresponding design requirements of a steel structure are illustrated.It is pointed out that direct application of the design concept for the ambient temperature to a fire safety design is unreasonable because in a fire situation,robustness should be the main concern for connections.The observations and conclusions drawn from a set of tests designed for this purpose are then reported.The relationships among three major parameters in a connection design,i.e.,the moment capacity,the axial force capacity and the rotational capacity of the connection are discussed and a solution for a performance-based connection design is proposed.
What problem does this paper attempt to address?