HPLC Determination of Trimetazidine Dihydrochloride and Its Relative Substances in Tablets

Jing Zhang
2009-01-01
Abstract:Objective:To develop an HPLC method for the determination of the content of trimetazidine dihydrochloride and its related substances in tablets.Methods:The separation was performed on a DiamonsilTM C18 column (5 μm,200 mm×4.6 mm).The mobile phase A was composed of water-5.5% sodium heptane sulfonate solution [adjusted to pH 3.0 with phosphoric acid solution]-methanol(100∶55∶587),the mobile phase B was methanol,a liner gradient was used as 0~30 min,25%~40% B.The flow rate was 1.0 mL·min-1and the detection wavelength was set at 210 nm.Results:A linearity between peak areas and trimetazidine dihydrochloride concentration was achieved in the rang of 1.01~4.04 μg·mL-1,with r=0.999 8.The average recovery was 100.1%(n=9).The detection limit was 0.60 ng·mL-1.Conclusions:The method is reliable,specific and accurate,it can be used for quality control of trimetazidine dihydrochloride tablets.