Determination of Alkaloids in Zhidaipian Tablets by high performance liquid chromatogram

Senke Hu,Yan Yu,Jiangli Miao
DOI: https://doi.org/10.3969/j.issn.1671-8259.2007.03.033
2007-01-01
Abstract:Objective: To establish a method of high performance liquid chromatogram (HPLC) for measuring matrine and oxymatrine in Zhidaipian Tablets. Methods: A Lichrospher-NH2 column(4.6 mm X 250 mm, 5 μm) was used with a mobile phase consisting of acetonitrile-ethanol-0.5 mol/L phosphoric acid (80:10: 10), and in a flow rate of 1.0 mL/min. The detective wavelength was 212 nm. Column temperature was room temperature and the injection quantity was 20 μL. Results: The samples were well separated. The linear range was the same for the target (1.0-10. μg/mL). The linear equations for matrine was C = 1.201 × 10-4 A + 0.161, the correlation coefficient was 0.9992, and for oxymatrine was C = 1.366 × 10-4 A + 0.221, while the correlation coefficient was 0.9996, respectively. The mean recovery rate were 99.9% and 99.4%, respectively. RSD was 1.48% and 4.33%, respectively (n = 6). Conclusion: The method is simple, reliable, accurate and can be used to the quality control of the Zhidaipian Tablets.
What problem does this paper attempt to address?