Mechanisms and Inhibition Method Investigation on Condensation Induced Water Hammer in an Equal-Height-difference Passive Heat Removal System

Zhiwei Wang,Yanping He,Zhongdi Duan,Chao Huang,Shiwen Liu,Mingzhi Li,Hongxiang Xue
DOI: https://doi.org/10.1016/j.applthermaleng.2023.121078
IF: 6.4
2023-01-01
Applied Thermal Engineering
Abstract:The equal-height-difference passive heat removal system utilizes the ocean as an ultimate heat sink for residual heat removal, demonstrating obvious advantages for ocean nuclear power plant applications. However, the structure with a zero-height difference can trigger the reverse flow of subcooled water. This could cause serious condensation induced water hammer events. In this study, a fully visual experimental setup was established to investigate the occurrence features. First, two kinds of formation mechanisms were defined by the visual experimental results. In this regard, the subcooling and the isolated steam slug are the necessary conditions for the formation and development. In addition, the occurrence positions were found to be concentrated in the test pipe section near the water tank. Then, a butterfly check valve was designed to avoid the condensation induced water hammer events based on the formation mechanisms. The experimental results showed that the check valve usage can effectively inhibit the reverse flow of the subcooled water and thus achieve its purpose of eliminating condensation induced water hammer events. Moreover, the check valve transforms the two-phase natural circulation flow from the condensation oscillation mode to the stable boiling two-phase flow mode. As a result, it enhances the two-phase natural circulation capacity.
What problem does this paper attempt to address?