Experimental investigation of the effect of geometrical and operating variables on condensation induced water hammer in horizontally oriented pipes

Anu Dutta,I. Thangamani,P. Goyal,V. Verma,J. Chattopadhyay,Seik Mansoor Ali,L. Raj
DOI: https://doi.org/10.1016/j.nucengdes.2024.113164
IF: 1.7
2024-03-31
Nuclear Engineering and Design
Abstract:Condensation-Induced Water Hammer (CIWH) phenomenon involves dynamic pressure changes caused by rapid condensation of steam in subcooled water. The magnitude of pressure spike is often large and can cause damage to the pipes and components in steam-water systems. Understanding the phenomena is vital for obtaining a safe and reliable design. This paper describes experimental investigations carried out in a specially designed facility called Water and Steam Interaction Facility (WASIF-I), that offers control over water and steam flow rates, can operate in co–, cross-, or counter-current flow mode and contains multiple injection locations. The occurrence of CIWH in horizontally oriented pipes filled with saturated steam is studied for the case where subcooled water is injected in cross-flow mode. The effect of geometrical and operating variables on the initiation of CIWH as well as peak pressure are brought out in this experimental work. A correlation to predict the critical minimum feed water flowrate necessary for triggering CIWH is developed based on multiple, nonlinear regression analysis of data from around 150 experiments. A regime map is presented that can be used as a guideline to preclude occurrence of CIWH.
nuclear science & technology
What problem does this paper attempt to address?