Behavior analysis of PEMFC with geometric configuration variation during multiple-step loading reduction process

Zhifeng Xia,Huicui Chen,Ruirui Zhang,Qianyao Weng,Tong Zhang,Pucheng Pei
DOI: https://doi.org/10.1016/j.apenergy.2023.121671
IF: 11.2
2023-01-01
Applied Energy
Abstract:Load shedding could be a solution to water accumulation alleviation during the operation of proton exchange membrane fuel cell (PEMFC) engines. In this paper, multiple-step loading reduction strategies based on two laboratory-scale (25 cm2) single PEMFCs (assembled with triple-serpentine and single-serpentine flow field plates on the both electrodes and thus named after cell TS and cell SS respectively) are experimentally discussed and evaluated. The real-time pressure evolution and HFR are recorded, compared and analyzed to characterize water transfer phenomenon among the components. The investigation results suggest that: 1. From the perspective of output voltage and power after load reduction, the number of reduction step has little effect on the output performance; 2. Cell TS exhibits better homogeneous trend of pressure drop although with less water removal quantity comparing with that of cell SS, which is resulted from multi-channel configuration; 3. The cathode pressure drop of cell SS decreases obviously throughout the experiment, indicating the convinced water removal capability of single-serpentine configuration; 4. Constant increase of HFR reflects membrane dehydration when the loading reduces. This paper demonstrates the possibility of removing accumulated liquid water by reducing the load of PEMFCs.
What problem does this paper attempt to address?