Application of Selective Non-catalytic Reduction Denitrification

Wenqing Li
2010-01-01
Abstract:The denitrification system of SG-1025/16.7-M313 UP boiler of active domestic 300 MW coal-fired unit was modified with selective non-catalytic reduction(SNCR) technique.The position and quantity of spray guns were determined by numerical simulation of computational fluid dynamics(CFD) and on-site test on boiler temperature field.The arrangement of fully telescopic long spray gun was adopted to improve the coverage of urea solution,thereby enhancing the rate of denitrification.Different combinations of spray gun were used to adapt to load changes of boiler and ensure the best response temperature window of reducing agent.The boiler operated normally after the modification with the mass concentration of NOx reduced from 360 mg/m3 to 210 mg/m3 and the denitrification efficiency up to 41.6%.