Electrical Impedance As Signal to Monitor Healthy State of Eardrum-Like Membranes

Jin Xie,Shih-Fu Ling
DOI: https://doi.org/10.1007/s12206-013-0606-9
IF: 1.81
2013-01-01
Journal of Mechanical Science and Technology
Abstract:Eardrum perforation is viewed as one kind of structural damage occurring in human being, which will cause loss of hearing when the damage becomes serious. This paper describes a preliminary concept to detect damage of eardrum-like membranes through measuring electrical impedance of a dynamic microphone. The dynamic microphone is inserted in one end of an ear canal-like tube and the eardrum-like membrane is attached at the other end of tube. Holes with different size are drilled in the membranes to represent the different damage levels. The electrical impedance of dynamic microphone is directly related to the mechanical impedance of the membrane, and any change in the electrical impedance signal can be considered an indication of change in the membrane integrity. For the different damage levels of membrane, variation of electrical impedance from the dynamic microphone is observed in experiment. Features are extracted from the curves of electrical impedance and used to train an artificial neural network. Through the trained neural network, damage in membrane can be monitored even in its incipient stage, and the damage levels can be easily estimated, which indicates electrical impedance is a good signal for non-destructive evaluation of structural health.
What problem does this paper attempt to address?