Simulation Characteristics of Liquid Metal Flow Limiters with Different Number of Pores

Aozheng Wang,Guoqiang Gao,Yaguang Ma,Liting Yan,Yu Xiang,Wei Peng,Bingyan You,Guangning Wu
DOI: https://doi.org/10.1109/icempe57831.2023.10139747
2023-01-01
Abstract:When a short-circuit fault occurs in a DC power system, the huge inrush short-circuit current will cause irreversible damage to the load and the power electronic components in the circuit. Based on the self-shrinkage effect of liquid metal, liquid metal flow limiter has a good application prospect in $D C$ system as a breaking device. In this paper, a liquid metal flow limiter model with different number of pores is established, the truncated arc initiation of liquid metal between different number of pores is compared and analyzed, and the temperature, pressure, electric field and energy density of different pore numbers are studied. In this paper, the truncated arc initiation time of the single-hole model is earlier and the response is rapid, and the temperature of the single aperture of the multi-hole model is lower than that of the single-hole model. The characteristic parameters such as pressure, electric field and current limiting effect of the three-hole model are better than the single-hole and two-hole models.
What problem does this paper attempt to address?