The effect of inlet vortex on Venturi flowmeter inflated measurement

WANG Zhiwu,YAO Likai,QI Baozhe,WANG Qian,GUI Nan,LIU Yang
DOI: https://doi.org/10.16791/j.cnki.sjg.2023.02.018
2023-01-01
Abstract:As a flow monitoring device for the second-loop main feedwater system(ARE) of a nuclear power plant,the Venturi flowmeter is critical to the accurate measurement of feedwater flow. During the switching of large and small valves in the ARE system, the Venturi flow measurement value may have fluctuation and false high phenomenon, which affects the normal operation of the reactor. This paper analyzes the effect of Venturi inlet vortex on false high of flow measurement based on computational fluid dynamics method for simplified structure and installation geometry. The results show that the inlet vortex increases the velocity at the Venturi throat leading to an increase in the measured differential pressure, and that the circumferential velocity distribution at the branch pipe during ARE valve switching amplifies this effect. In addition, when the main valve opening is gradually increased, it can suppress the intensity of the single vortex caused by the branch jet and reduce the false high of flow measurement.